State applicable energy ashrae zone minimum r value state local ms mississippi ashrae 90 1 2010 2 r 20.
Flat roof u value 2013.
Column b is for other extensions upgraded existing thermal elements non exempt conservatories and conversion of unheated.
R value state local al alabama 2015 alabama commercial energy code 2 r 25 3 r 25 state.
Here s my 2 cents and insulation guide for a cold flat roof concrete slab floor internal stud wall and to find out what type and thickness of insulation.
The tables below show the suggested u values in england wales and scotland.
Insulation for flat roofs pitched roofs and balconies and terraces.
Insulation for walls including cavity walls solid walls and timber or steel framed walls.
This is placed over the roof joists and a board normally external ply is laid on top.
Epdm rubber roof covering 19mm ply 50mm ventilated air layer protect vp400 plus lr membrane sip at specified thickness protect vc foil ultra insulating a vcl 25mm service void 50mm gyproc thermaline super.
Flat epdm roof description.
These are expressed as a u value which needs to be achieved.
A lower u value indicates better insulation properties hence u value requirements usually specify a maximum value.
Get a u value calculation from our free online u value calculator or our technical department.
Where not exempt a conservatory heated or unheated should be built to the same maximum u values as any other new work as listed in columns b and c of the table in clause 6 2 9 with the exception that glazing and framing elements forming the walls or roof of a conservatory are unlimited in area and should have a maximum area weighted.
Flat roof u value 0 18 w m2k 2 warm deck flat roof the type of insulation for this is usually of a rigid type and the thickness will vary depending on the manufacturer s specifications.
For the majority of flat roofs built up in a series of material layers each of a consistent thickness and performance the most appropriate calculation type is the combined method detailed in bs en iso 6946.
Check our library of roof u value calculations.
U value of a flat roof.
To comply with part l of the building regulations 2010 all roofs to rooms except those in unheated buildings should be thermally insulated to a maximum u value of of 0 18 w m k.
The required u value will depend on the location of the project england scotland or wales type of building domestic or non domestic and the application floor wall or roof.
Thickness varies according to the manufacturer s specifications.